Single-phase power failure simulator, meets IEC/EN 61000-4-11/-4-29 and GB/T 17626.11/.29
◆ Input voltage: maximum 300Vac/dc
◆ Rated current: 16A continuous
◆ Switching time: 1-5μs@100Ω load
◆ Impulse current: >500A
◆ Drop level: 0%-100%**
◆ Voltage interruption: 0.5 cycle-999 cycle / 0.1ms-999min
◆ Cycle cycle: 1 cycle-999 cycle / 10ms-999min
◆ Test time (Cycle): 1s-999min (999 times)
◆ 7'' touch color screen
* HPFS 161P: Independent single-phase fault power supply
HCOMPACT: Compatible with pulse train and lightning surge functions, please refer to HCOMPACT 5 and HCOMPACT 7 for details
* * The external voltage regulator outputs any Dips voltage, which can meet the amplitude requirement of >100%
The DC drop function can also be integrated to realize automatic switching between AC and DC
Option HV1P16T: single-phase AC fault power supply, maximum 16A
Option HVDC xxx: DC fault power supply, output voltage & current can be customized
Option HV1P16VAR: Programmable voltage change test module, maximum 16A, fully compatible with the latest version of IEC 61000-4-11