CN
Product center

Latest Information
Home > Product center > Voltage dips, interruption and voltage change Generator

Voltage dips, interruption and voltage change Generator

  • HPFS 303P / HPFS 603P / HPFS 1003P / HPFS 2003P

    HPFS 303P / HPFS 603P / HPFS 1003P / HPFS 2003P
Details

Three-phase power failure simulator, meets IEC/EN 61000-4-11/-4-29/-4-34 and GB/T 17626.11/.29/.34

◆ Input voltage: 4×480Vac*

◆ Rated current: 32A/64A/100A/200A continuous

◆ Switching time: 1-5μs @100Ω and 50Ω load (<75A)

                             1-50μs @25Ω load (>75A)

◆ Inrush current: >1000A (three-phase)

◆ Drop level: 0%-100%**

◆ Voltage interruption: 0.5 cycle-999 cycle / 0.1ms-999min

◆ Cycle cycle: 1 cycle-999 cycle / 10ms-999min

◆ Test time (Cycle): 1s-999min (999 times)

◆ Drop method: L1L2/L2L3/L3L1/L1N/L2N/L3N/L1L2L3

◆ 7'' touch color screen

* Option 10KDC: 1000Vdc / 690Vac

* * The external voltage regulator outputs any Dips voltage, which can meet the amplitude requirement of >100%

    The DC drop function can also be integrated to realize automatic switching between AC and DC

  Option HV3PxxT: Three-phase AC fault power supply, maximum 200A, with Phase shift function, fully compatible with the latest version of IEC 61000-4-34

  Option HVDC xxx: DC fault power supply, output voltage & current can be customized

  Option HV1PxxVAR: Programmable voltage change test module, maximum 200A, fully compatible with the latest version of IEC 61000-4-34